Configure Interop mode
Contents
Backup config
configupload
Firmware and Software Version Compatibility
list all in Interopmode Supported Release will be available soon. In the meantime refer please the FabricOS Release Notes.
Domain ID setting
domainsshow IBM_B24_02:admin> switchdisable IBM_B24_02:admin> switchshow switchName: IBM_B24_02 switchType: 71.2 switchState: Offline switchMode: Native switchRole: Disabled switchDomain: 1 (unconfirmed) switchId: fffc01 switchWwn: 10:00:50:eb:1a:09:40:52 zoning: OFF switchBeacon: OFF IBM_B24_02:admin> configure Configure... Fabric parameters (yes, y, no, n): [no] yes Domain: (1..239) [1] 2 IBM_B24_02:admin> switchenable
interopmode setting
- check interopmode
1 interopmode
- setting to IM3
1 interopmode 3
- IM0 - Brocade Native
- IM1 - Open-Mode
( Notice: InteropMode 1 - former Open Mode - is no longer supported in Fabric OS v6.0 and above, but is continued supported in Fabric OS v2.x; v3.x; v4.x and v5.x )
- IM2 - McDATA Fabric Mode
- IM3 - Open fabric Mode
- FOS features restrictions IM0 versus IM2 and IM3
1 IBM_B24_02:admin> switchshow
2 switchName: IBM_B24_02
3 switchType: 71.2
4 switchState: Online
5 switchMode: Native
6 switchRole: Subordinate
7 switchDomain: 2
8 switchId: fffc02
9 switchWwn: 10:00:50:eb:1a:09:40:52
10 zoning: ON (ZONE_CONFIG)
11 switchBeacon: OFF
12
13 Index Port Address Media Speed State Proto
14 ==============================================
15 0 0 020000 id N8 Online FC E-Port 10:00:00:05:33:f9:ff:fb "BladeH_BR_02" (downstream)
16 1 1 020100 id N8 Online FC F-Port 50:05:07:68:02:35:8b:8f
17 2 2 020200 id N8 Online FC F-Port 50:05:07:68:02:15:8b:90
18 3 3 020300 id N2 Online FC F-Port 21:00:00:d0:23:10:00:01
19 4 4 020400 id N8 Online FC E-Port 10:00:00:05:33:d3:4a:3e "brocade8Gb_1" (upstream)
20 5 5 020500 id N8 No_Light FC
21 6 6 020600 id N4 Online FC F-Port 50:0a:09:82:88:2a:60:73
22 7 7 020700 id N4 Online FC F-Port 50:0a:09:82:98:2a:60:73
23 8 8 020800 id N8 No_Light FC
24 9 9 020900 id N8 No_Light FC
IBM BladeE_FC_SW02
nys23bb89:USERID> configure
Configure...
Fabric parameters (yes, y, no, n): [no] yes
Domain: (1..239) [1] 101
R_A_TOV: (4000..120000) [10000]
E_D_TOV: (1000..5000) [2000]
WAN_TOV: (0..30000) [0]
MAX_HOPS: (7..19) [7]
Data field size: (256..2112) [2112]
Sequence Level Switching: (0..1) [0]
Disable Device Probing: (0..1) [0]
Suppress Class F Traffic: (0..1) [0]
Switch PID Format: (1..2) [1]
Per-frame Route Priority: (0..1) [0]
Long Distance Fabric: (0..1) [0]
BB credit: (1..27) [16]
Insistent Domain ID Mode (yes, y, no, n): [no]
Virtual Channel parameters (yes, y, no, n): [no]
Zoning Operation parameters (yes, y, no, n): [no]
RSCN Transmission Mode (yes, y, no, n): [no]
Arbitrated Loop parameters (yes, y, no, n): [no]
System services (yes, y, no, n): [no]
Portlog events enable (yes, y, no, n): [no]
ssl attributes (yes, y, no, n): [no]
http attributes (yes, y, no, n): [no]
snmp attributes (yes, y, no, n): [no]
rpcd attributes (yes, y, no, n): [no]
cfgload attributes (yes, y, no, n): [no]
webtools attributes (yes, y, no, n): [no]
WARNING: The domain ID will be changed. The port level zoning may be affectednys23bb89:USERID> switchName BladeE_FC_SW02
Committing configuration...
Done.
BladeE_FC_SW02:USERID>
BladeE_FC_SW02:USERID> switchEnable
BladeE_FC_SW02:USERID> switchShow
BladeE_FC_SW02:USERID> msPlMgmtDeactivate
Switch is in Offline state.
BladeE_FC_SW02:USERID> interopMode
InteropMode: Off
Usage: InteropMode 0|1
0: to turn it off
1: to turn it on
BladeE_FC_SW02:USERID> interopMode 1
The switch effective configuration will be lost when the operating mode is changed; do you want to continue? (yes, y, no, n): [no] yes
Interopmode is enabled
Note: It is recommended that you reboot this switch for the new change to take effect.
BladeE_FC_SW02:USERID> fastBoot
Broadcast message from root (pts/0) Wed Aug 1 11:02:57 2001...
The system is going down for reboot NOW !!BladeE_FC_SW02:USERID> portcfgpersistentenable 15 BladeE_FC_SW02:USERID> switchshow switchName: BladeE_FC_SW02 switchType: 37.1 switchState: Online switchMode: Native switchRole: Principal switchDomain: 107 switchId: fffc6b switchWwn: 10:00:00:05:1e:05:9c:df zoning: OFF switchBeacon: OFF Area Port Media Speed State ============================== 0 0 id N4 No_Light 1 1 cu N4 Online F-Port 21:00:00:24:ff:2b:e9:15 2 2 cu N4 Online F-Port 21:01:00:1b:32:b7:fe:50 3 3 cu N4 Online F-Port 10:00:00:00:c9:b6:0b:85 4 4 cu N4 Online F-Port 10:00:00:00:c9:b6:15:6f 5 5 cu N4 Online F-Port 10:00:00:90:fa:49:8d:bb 6 6 cu N4 Online F-Port 10:00:00:90:fa:49:aa:bf 7 7 cu AN No_Sync 8 8 cu N4 Online F-Port 21:00:00:24:ff:59:f5:b5 9 9 cu N4 Online F-Port 21:00:00:24:ff:59:f5:c3 10 10 cu N4 Online F-Port 21:00:00:24:ff:59:f5:91 11 11 cu AN No_Sync 12 12 cu AN No_Sync 13 13 cu AN No_Sync 14 14 cu AN No_Sync 15 15 id N4 Online E-Port segmented,(FCSW version incompat) 16 16 -- N4 No_Module Disabled (Persistent) 17 17 -- N4 No_Module Disabled (Persistent) 18 18 -- N4 No_Module Disabled (Persistent) 19 19 -- N4 No_Module Disabled (Persistent) BladeE_FC_SW02:USERID> portcfgpersistentenable Slot 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 ---------+---+---+---+---+---+---+---+---+---+---+---+---+---+---+---+--- Enabled YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES Slot 0 16 17 18 19 ---------+---+---+---+--- Enabled - - - -
References
http://community.brocade.com/t5/Fibre-Channel-SAN/problem-with-module-for-IBM-bladecenter/td-p/14399
http://community.brocade.com/t5/Fibre-Channel-SAN/Swap-configuration-port-Dynamic-POD/td-p/26750