Fabric Interconnect

Upgrade FI-UCSM From 3.2(3b) to 4.0(1c)

Cisco strongly recommends that you use Auto Install to upgrade a Cisco UCS domain.

Prerequisites for Upgrade to Cisco UCS Manager Release 4.0

Upgrading the Infrastructure software bundle (A bundle) directly to Cisco UCS Manager Release 4.0(x) is supported from Release 3.1(1) and later releases. While upgrading from releases earlier than Release 3.1(1), you must upgrade to Release 3.1(x) or 3.2(x) first for A, B, and C bundles, and then upgrade to Release 4.0(x).

https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ucs-manager/GUI-User-Guides/Firmware-Mgmt/4-0/b_UCSM_GUI_Firmware_Management_Guide_4-0/b_UCSM_GUI_Firmware_Management_Guide_4-0_chapter_010.html#concept_yh1_lsw_wdb

UCS-A# scope security
UCS-A /security # scope keyring keyring-name 
UCS-A /security/keyring # show detail

Required Order of Steps for Auto Install

If you want to upgrade all components in a Cisco UCS domain to the same package version, you must run the stages of Auto Install in the following order:

This order enables you to schedule the server firmware upgrades during a different maintenance window than the infrastructure firmware upgrade.

Creating an All Configuration Backup File

This procedure assumes that you do not have an existing backup operation for an All Configuration backup file.

Enters system mode.

    ftp:// username@hostname / path
    scp:// username@hostname / path
    sftp:// username@hostname / path
    tftp:// hostname : port-num / path

Commits the transaction.

Disabling Smart Call Home

BGY-NEW-HX-B /system # scope monitoring 
BGY-NEW-HX-B /monitoring #  scope callhome 
BGY-NEW-HX-B /monitoring/callhome # disable 
BGY-NEW-HX-B /monitoring/callhome # 
BGY-NEW-HX-B /monitoring/callhome # commit-buffer
BGY-NEW-HX-B /monitoring/callhome # show detail

Callhome:
    Admin State: Off
    Throttling State: On
    Contact Information:
    Customer Contact Email:
    From Email:
    Reply To Email:
    Phone Contact e.g., +1-011-408-555-1212:
    Street Address:
    Contract Id:
    Customer Id:
    Site Id:
    Switch Priority: Debugging
    SMTP Server Address:
    SMTP Server Port: 25
    Current Task:

Verifying the Operability of a Fabric Interconnect

BGY-NEW-HX-B# scope fabric-interconnect a
BGY-NEW-HX-B /fabric-interconnect # show

Fabric Interconnect:
    ID   OOB IP Addr     OOB Gateway     OOB Netmask     OOB IPv6 Address OOB IPv6 Gateway Prefix Operability
    ---- --------------- --------------- --------------- ---------------- ---------------- ------ -----------
    A    10.254.253.77   10.254.253.254  255.255.255.0   ::               ::               64     Operable
BGY-NEW-HX-B /fabric-interconnect # exit
BGY-NEW-HX-B# scope fabric-interconnect b
BGY-NEW-HX-B /fabric-interconnect # show

Fabric Interconnect:
    ID   OOB IP Addr     OOB Gateway     OOB Netmask     OOB IPv6 Address OOB IPv6 Gateway Prefix Operability
    ---- --------------- --------------- --------------- ---------------- ---------------- ------ -----------
    B    10.254.253.78   10.254.253.254  255.255.255.0   ::               ::               64     Operable

Verifying the High Availability Status and Roles of a Cluster Configuration

BGY-NEW-HX-B# show cluster state 
Cluster Id: 0xaded5a7ccf6611e7-0xb59400defb68c3a1

B: UP, PRIMARY
A: UP, SUBORDINATE

HA READY

Configuring the Default Maintenance Policy

BGY-NEW-HX-B# scope org /
BGY-NEW-HX-B /org # scope maint-policy default
BGY-NEW-HX-B /org/maint-policy # set reboot-policy user-ack
BGY-NEW-HX-B /org/maint-policy* # commit-buffer 
BGY-NEW-HX-B /org/maint-policy # show

Maintenance Policy:
    Name       Schedule
    ---------- --------
    default
BGY-NEW-HX-B /org/maint-policy # show detail 

Maintenance Policy:
    Name: default
    Schedule:
    Description:
    Policy Owner: Local
    Reboot Policy: User Ack
    Config Trigger: None
    Soft Shutdown Timer: 150 Secs
BGY-NEW-HX-B /org/maint-policy # 

Disabling the Management Interface

BGY-NEW-HX-B# scope monitoring 
BGY-NEW-HX-B /monitoring # set mgmt-if-mon-policy admin-state enabled
BGY-NEW-HX-B /monitoring # commit-buffer
BGY-NEW-HX-B /monitoring # 

Verifying the Status of an I/O Module

Not have

Verifying the Status of a Server

OK as bellow

BGY-NEW-HX-B# scope server 1
BGY-NEW-HX-B /server # show status 
Server  Slot Status                       Availability Overall Status   Discovery
------- -------------------------         ------------ --------------------- ---------
1       N/A                               Available    Unassociated          Complete
BGY-NEW-HX-B /server # show status detail 
Server 1:
    Conn Path: A,B
    Conn Status: A,B
    Managing Instance: B
    Availability: Available
    Admin State: In Service
    Overall Status: Unassociated
    Oper Qualifier: N/A
    Discovery: Complete
    Current Task:
    Check Point: Discovered

BGY-NEW-HX-B /server # show adapter status 
Server 1:
    Overall Status
    --------------
    N/A

Failed discovered as bellow

BGY-NEW-HX-B# scope server 2
BGY-NEW-HX-B /server # show sta
stats   status  

BGY-NEW-HX-B /server # show status 
Server  Slot Status                       Availability Overall Status   Discovery
------- -------------------------         ------------ --------------------- ---------
2       N/A                               Unavailable  Discovery             In Progress
BGY-NEW-HX-B /server # show status detail 
Server 2:
    Conn Path: A
    Conn Status: A
    Managing Instance: A
    Availability: Unavailable
    Admin State: In Service
    Overall Status: Restart
    Oper Qualifier: N/A
    Discovery: In Progress
    Current Task: Preparing to check hardware configuration server sys/rack-unit-2(FSM-STAGE:sam:dme:ComputePhysicalHardreset:PreSanitize)
    Check Point: Shallow Checkpoint

Verifying the Ethernet Data Path

BGY-NEW-HX-B# connect nxos b
Cisco Nexus Operating System (NX-OS) Software
TAC support: http://www.cisco.com/tac
Copyright (c) 2002-2016, Cisco Systems, Inc. All rights reserved.
The copyrights to certain works contained in this software are
owned by other third parties and used and distributed under
license. Certain components of this software are licensed under
the GNU General Public License (GPL) version 2.0 or the GNU
Lesser General Public License (LGPL) Version 2.1. A copy of each
such license is available at
http://www.opensource.org/licenses/gpl-2.0.php and
http://www.opensource.org/licenses/lgpl-2.1.php
BGY-NEW-HX-B(nxos)# 
BGY-NEW-HX-B(nxos)# show interface brief | grep -v down 

--------------------------------------------------------------------------------
Ethernet      VLAN    Type Mode   Status  Reason                   Speed     Port
Interface                                                                    Ch #
--------------------------------------------------------------------------------
Eth1/1        1       eth  vntag  up      none                        10G(D) --
Eth1/2        1       eth  vntag  up      none                        10G(D) --
Eth1/3        1       eth  vntag  up      none                        10G(D) --
Eth1/4        1       eth  vntag  up      none                        10G(D) --
Eth1/5        1       eth  vntag  up      none                        10G(D) --
Eth1/6        1       eth  vntag  up      none                        10G(D) --
Eth1/7        1       eth  vntag  up      none                        10G(D) --
Eth1/8        1       eth  vntag  up      none                        10G(D) --

--------------------------------------------------------------------------------
Port   VRF          Status IP Address                              Speed    MTU
--------------------------------------------------------------------------------

--------------------------------------------------------------------------------
Vethernet     VLAN   Type Mode   Status  Reason                    Speed
--------------------------------------------------------------------------------
Veth32769     1      virt trunk  up      none                     auto     
Veth32770     1      virt trunk  up      none                     auto     
Veth32771     1      virt trunk  up      none                     auto     
Veth32772     1      virt trunk  up      none                     auto     
Veth32773     1      virt trunk  up      none                     auto     
Veth32774     1      virt trunk  up      none                     auto     
Veth32775     1      virt trunk  up      none                     auto     
Veth32776     1      virt trunk  up      none                     auto     

-------------------------------------------------------------------------------
Interface Secondary VLAN(Type)                    Status Reason                 
-------------------------------------------------------------------------------
BGY-NEW-HX-B(nxos)# show interface brief | grep -v down | wc -l
33


BGY-NEW-HX-B(nxos)# show platform fwm info hw-stm
HW STM Contents
dleft loc   - bucket_type:line:bucket_number
misc        - learn_type:ecc:valid:fcf
cdce format - ig:ul:switch_id:subswitch_id:end_node_id:pbp_idx:local_id

VLAN   MAC Address      Port           loc      misc    cdce
------+----------------+--------------+--------+-------+--------------------
1.4043 380e.4d16.94e7   Eth1/4         1:51:0   0:0:1:0 2.a.bc.0.0.6 (e:0)
1.4044 380e.4d16.bd45   vif56          1:190:0  0:0:1:0 6.a.bc.0.0.8 (e:1)
1.4044 380e.4d16.9505   vif52          1:815:0  0:0:1:0 6.a.bc.0.0.6 (e:1)
vsan1  0efc.00ff.fc4d   sup-eth1       1:1221:0 0:0:1:1 2.0.0.0.0.3 (e:0)
1.4043 3890.a5bd.3a31   Eth1/6         1:1421:0 0:0:1:0 2.a.bc.0.0.b (e:0)
1.4044 3890.a5bd.3a4f   vif55          1:1529:0 0:0:1:0 6.a.bc.0.0.b (e:1)
1.4043 380e.4d16.8f21   Eth1/2         1:1532:0 0:0:1:0 2.a.bc.0.0.7 (e:0)
1.4044 500f.809f.c294   vif51          1:1597:0 0:0:1:0 6.a.bc.0.0.9 (e:1)
1.4043 380e.4d16.bd27   Eth1/3         1:1931:0 0:0:1:0 2.a.bc.0.0.8 (e:0)
1.4043 500f.809f.c036   Eth1/7         1:2624:0 0:0:1:0 2.a.bc.0.0.a (e:0)
1.4044 380e.4d16.8f3f   vif69          1:2659:0 0:0:1:0 6.a.bc.0.0.7 (e:1)
1.4043 380e.4d16.9547   Eth1/1         1:3266:0 0:0:1:0 2.a.bc.0.0.5 (e:0)
1.4044 380e.4d16.9565   vif68          1:3268:0 0:0:1:0 6.a.bc.0.0.5 (e:1)
1.4044 500f.809f.c054   vif53          1:3445:0 0:0:1:0 6.a.bc.0.0.a (e:1)
1.4043 500f.809f.be56   Eth1/8         1:3690:0 0:0:1:0 2.a.bc.0.0.c (e:0)
1.4044 500f.809f.be74   vif54          1:3692:0 0:0:1:0 6.a.bc.0.0.c (e:1)
1.4043 500f.809f.c276   Eth1/5         1:3950:0 0:0:1:0 2.a.bc.0.0.9 (e:0)
14.1   0efc.00ff.fc4d   sup-eth1       1:3951:0 0:0:1:0 2.a.bc.0.0.3 (e:0)
in-0   00de.fb68.c400   convert-err    3:0:1016 0:0:1:0 2.a.bc.0.0.0 (e:0)
14.407 0efc.0068.c400   convert-err    3:0:1017 0:0:1:0 2.a.bc.0.0.0 (e:0)
in-0   ffff.ffff.ffff   midx 8189      3:0:1018 0:0:1:0 1.0.0.0.1f.fd (e:0)
in-0   0100.5e00.0000   midx 8189      3:0:1019 0:0:1:0 1.0.0.0.1f.fd (e:0)
in-0   0100.5e00.0000   midx 8191      3:0:1020 0:0:1:0 1.0.0.0.1f.ff (e:0)
in-0   0100.0000.0000   midx 8190      3:0:1021 0:0:1:0 1.0.0.0.1f.fe (e:0)
DA hit 36569 miss 50651   SA ig_miss 27085 eg_miss 371035
Total addresses: 24 (unreserved entries -104)

BGY-NEW-HX-B(nxos)# show platform fwm info hw-stm | grep '1.' | wc -l
26

Verifying the Data Path for Fibre Channel End-Host Mode

BGY-NEW-HX-B(nxos)#  show npv flogi-table 
No flogi sessions found.

Downloading Firmware Images to the Fabric Interconnect from a Remote Location

UCS-A# scope firmware
UCS-A /firmware # download image scp://user1@192.168.10.10/images/ucs-k9-bundle.1.0.0.988.bin
OR
download image usbB:/username/ucs-k9-bundle-b-series.3.0.1a.B.bin
UCS-A /firmware # show download-task

Displaying the Firmware Package Download Status

BGY-NEW-HX-B# scope firmware 
BGY-NEW-HX-B /firmware # show download-task 

Download task:
    File Name Protocol Server                                Userid          State
    --------- -------- ------------------------------------- --------------- -----
    ucs-catalog.3.2.2b.T.bin
              Local    local                                                 Downloaded
    ucs-k9-bundle-b-series.3.2.2b.B.bin
              Local    local                                                 Downloaded
    ucs-k9-bundle-c-series.3.2.2b.C.bin
              Local    local                                                 Downloaded
    ucs-k9-bundle-infra.3.2.2b.A.bin
              Local    local                                                 Downloaded

BGY-NEW-HX-B /firmware # show image

Displaying All Available Packages on the Fabric Interconnect

BGY-NEW-HX-B /firmware # show package 
Name                                          Version
--------------------------------------------- -------
ucs-catalog.3.2.2b.T.bin                      3.2(2b)T
ucs-k9-bundle-b-series.3.1.2e.B.bin           3.1(2e)B
ucs-k9-bundle-b-series.3.2.2b.B.bin           3.2(2b)B
ucs-k9-bundle-c-series.3.1.2e.C.bin           3.1(2e)C
ucs-k9-bundle-c-series.3.2.2b.C.bin           3.2(2b)C
ucs-k9-bundle-infra.3.1.2e.A.bin              3.1(2e)A
ucs-k9-bundle-infra.3.2.2b.A.bin              3.2(2b)A

BGY-NEW-HX-B /firmware # show package ucs-k9-bundle-c-series.3.2.2b.C.bin expand
Package ucs-k9-bundle-c-series.3.2.2b.C.bin:
    Images:
        ucs-3260.3.0.3e.bin
        ucs-adaptor-pcie-ucsc-pcie-x710ta4.800031CA-1.810.8.bin
        ucs-c-amd-video-7150x2.015.049.000.016.007518_113-8747CA-102.bin
        ucs-c-emulex-pci-lpe31002.11.2.156.27.bin
        ucs-c-fusion-io-pfio1000mp.8.9.9.118194.bin
        ucs-c-fusion-io-pfio1000mps.8.9.9.118194.bin
        ucs-c-fusion-io-pfio1205m.7.1.17.bin

Checking the Available Space on a Fabric Interconnect

BGY-NEW-HX-B /fabric-interconnect # show storage 

Storage on local flash drive of fabric interconnect:
    Partition        Size (MBytes)    Used Percentage
    ---------------- ---------------- ---------------
    bootflash        16329            37
    opt              3877             2
    spare            5744             5
    usbdrive         Nothing          Empty
    var_sysmgr       2000             4
    var_tmp          600              1
    volatile         240              Empty
    workspace        3852             1

Upgrade the Infrastructure Firmware with Auto Install

If your Cisco UCS domain does not use an NTP server to set the time, make sure that the clocks on the primary and secondary fabric interconnects are in sync. You can do this by configuring an NTP server in Cisco UCS Manager or by syncing the time manually.

BGY-NEW-HX-A# show clock
Thu Nov 23 09:38:34 UTC 2017
BGY-NEW-HX-A# 

BGY-NEW-HX-B# show clock
Thu Nov 23 09:38:32 UTC 2017
BGY-NEW-HX-B#

BGY-NEW-HX-B /firmware # show package 
Name                                          Version
--------------------------------------------- -------
ucs-catalog.3.2.2b.T.bin                      3.2(2b)T
ucs-k9-bundle-b-series.3.1.2e.B.bin           3.1(2e)B
ucs-k9-bundle-b-series.3.2.2b.B.bin           3.2(2b)B
ucs-k9-bundle-c-series.3.1.2e.C.bin           3.1(2e)C
ucs-k9-bundle-c-series.3.2.2b.C.bin           3.2(2b)C
ucs-k9-bundle-infra.3.1.2e.A.bin              3.1(2e)A
ucs-k9-bundle-infra.3.2.2b.A.bin              3.2(2b)A
BGY-NEW-HX-B /firmware # 
BGY-NEW-HX-B /firmware # scope firmware 
BGY-NEW-HX-B /firmware # scope auto-install 
BGY-NEW-HX-B /firmware/auto-install # install infra infra-vers 3.2(2b)A
This operation upgrades firmware on UCS Infrastructure Components
(UCS manager, Fabric Interconnects and IOMs).
Here is the checklist of things that are recommended before starting Auto-Install
(1) Review current critical/major faults
(2) Initiate a configuration backup
(3) Check if Management Interface Monitoring Policy is enabled
(4) Check if there is a pending Fabric Interconnect Reboot activitiy
(5) Ensure NTP is configured
(6) Check if any hardware (fabric interconnects, io-modules, servers or adapters) is unsupported in the target release
Do you want to proceed? (yes/no):

Triggering Install-Infra with:
   Infrastructure Pack Version: 3.2(2b)A

Acknowledging the Reboot of the Primary Fabric Interconnect

Caution 

To upgrade with minimal disruption, you must confirm the following:

    Ensure that all the IOMs that are attached to the Fabric Interconnect are up before you acknowledge the reboot of the Fabric Interconnect. If all IOMs are not up, all the servers connected to the Fabric Interconnect will immediately be re-discovered and cause a major disruption.

    Ensure that both of the Fabric Interconnects and the service profiles are configured for failover.

    Verify that the data path has been successfully restored from the secondary Fabric Interconnect before you acknowledge the reboot of the primary Fabric Interconnect. For more information, see Verification that the Data Path is Ready.

After you upgrade the infrastructure firmware, Install Infrastructure Firmware automatically reboots the secondary fabric interconnect in a cluster configuration. However, you must acknowledge the reboot of the primary fabric interconnect. If you do not acknowledge the reboot, Install Infrastructure Firmware waits indefinitely for that acknowledgment rather than completing the upgrade. 

BGY-NEW-HX-B# show cluster state
Cluster Id: 0xaded5a7ccf6611e7-0xb59400defb68c3a1

B: UP, PRIMARY, (Management services: INIT IN PROGRESS)
A: UP, SUBORDINATE

HA NOT READY
Management services: initialization in progress on local Fabric Interconnect

BGY-NEW-HX-A# scope firmware   
BGY-NEW-HX-A /firmware # scope auto-install 
BGY-NEW-HX-A /firmware/auto-install # acknowledge primary fabric-interconnect reboot 
BGY-NEW-HX-A /firmware/auto-install* # commit-buffer 
BGY-NEW-HX-A /firmware/auto-install # show cluster state 
Cluster Id: 0xaded5a7ccf6611e7-0xb59400defb68c3a1

A: UP, SUBORDINATE
B: UP, PRIMARY

HA READY
BGY-NEW-HX-A /firmware/auto-install # 

Viewing the Status of the FSM During An Infrastructure Firmware Upgrade

BGY-NEW-HX-A# scope firmware   
BGY-NEW-HX-A /firmware # scope auto-install 
BGY-NEW-HX-A /firmware/auto-install # show fsm status expand


    FSM Status:

        Affected Object: sys/fw-system/fsm
        Current FSM: Deploy
        Status: In Progress
        Completion Time:
        Progress (%): 90

        FSM Stage:

        Order  Stage Name                               Status       Try
        ------ ---------------------------------------- ------------ ---
        1      DeployWaitForDeploy                      Success      0
        2      DeployResolveDistributableNames          Skip         0
        3      DeployResolveDistributable               Skip         0
        4      DeployResolveImages                      Skip         0
        5      DeployDownloadImages                     Skip         0
        6      DeployCopyAllImagesToPeer                Skip         0
        7      DeployInternalBackup                     Skip         0
        8      DeployPollInternalBackup                 Success      0
        9      DeployActivateUCSM                       Skip         0
        10     DeployPollActivateOfUCSM                 Success      0
        11     DeployUpdateIOM                          Skip         0
        12     DeployPollUpdateOfIOM                    Skip         0
        13     DeployActivateIOM                        Skip         0
        14     DeployPollActivateOfIOM                  Skip         0
        15     DeployFabEvacOnRemoteFI                  Skip         0
        16     DeployPollFabEvacOnRemoteFI              Skip         0
        17     DeployActivateRemoteFI                   Success      0
        18     DeployPollActivateOfRemoteFI             In Progress  1
        19     DeployFabEvacOffRemoteFI                 Pending      0
        20     DeployPollFabEvacOffRemoteFI             Pending      0
        21     DeployWaitForUserAck                     Pending      0
        22     DeployPollWaitForUserAck                 Pending      0
        23     DeployFailOverToRemoteFI                 Pending      0
        24     DeployPollFailOverToRemoteFI             Pending      0
        25     DeployActivateLocalFI                    Pending      0
        26     DeployPollActivateOfLocalFI              Pending      0
        27     DeployActivateUCSMServicePack            Pending      0
        28     DeployPollActivateOfUCSMServicePack      Pending      0

20 minutes ago

BGY-NEW-HX-B /firmware/auto-install # show fsm status expand


    FSM Status:

        Affected Object: sys/fw-system/fsm
        Current FSM: Deploy
        Status: In Progress
        Completion Time:
        Progress (%): 90

        FSM Stage:

        Order  Stage Name                               Status       Try
        ------ ---------------------------------------- ------------ ---
        1      DeployWaitForDeploy                      Success      0
        2      DeployResolveDistributableNames          Skip         0
        3      DeployResolveDistributable               Skip         0
        4      DeployResolveImages                      Skip         0
        5      DeployDownloadImages                     Skip         0
        6      DeployCopyAllImagesToPeer                Skip         0
        7      DeployInternalBackup                     Skip         0
        8      DeployPollInternalBackup                 Success      0
        9      DeployActivateUCSM                       Skip         0
        10     DeployPollActivateOfUCSM                 Success      0
        11     DeployUpdateIOM                          Skip         0
        12     DeployPollUpdateOfIOM                    Skip         0
        13     DeployActivateIOM                        Skip         0
        14     DeployPollActivateOfIOM                  Skip         0
        15     DeployFabEvacOnRemoteFI                  Skip         0
        16     DeployPollFabEvacOnRemoteFI              Skip         0
        17     DeployActivateRemoteFI                   Success      0
        18     DeployPollActivateOfRemoteFI             In Progress  4
        19     DeployFabEvacOffRemoteFI                 Pending      0
        20     DeployPollFabEvacOffRemoteFI             Pending      0
        21     DeployWaitForUserAck                     Pending      0
        22     DeployPollWaitForUserAck                 Pending      0
        23     DeployFailOverToRemoteFI                 Pending      0
        24     DeployPollFailOverToRemoteFI             Pending      0
        25     DeployActivateLocalFI                    Pending      0
        26     DeployPollActivateOfLocalFI              Pending      0
        27     DeployActivateUCSMServicePack            Pending      0
        28     DeployPollActivateOfUCSMServicePack      Pending      0
BGY-NEW-HX-B /firmware/auto-install # 

BGY-NEW-HX-B /firmware/auto-install # show fsm status expand detail | grep Prog
        Status: In Progress
        Progress (%): 98
            Status: In Progress

BGY-NEW-HX-A /firmware/auto-install # show fsm status       


    FSM 1:
        Remote Result: Not Applicable
        Remote Error Code: None
        Remote Error Description:
        Status: Nop
        Previous Status: Deploy Success
        Timestamp: 2017-11-23T10:21:32.159
        Try: 0
        Progress (%): 100
        Current Task:
        Flags: 0

BGY-NEW-HX-A /firmware/auto-install # show cluster state 
Cluster Id: 0xaded5a7ccf6611e7-0xb59400defb68c3a1

A: UP, PRIMARY
B: UP, SUBORDINATE

HA READY
BGY-NEW-HX-A /firmware/auto-install # 

Confirm that upgrade is complete

Step 1          Log in to Cisco UCS Manager to ensure that the HX nodes have no pending server activities.

From Server > Pending Activities tab check for all server activities.
Step 2          Confirm that the HX nodes match the expected firmware version.

In Cisco UCS Manager, from Equipment > Firmware Management > Installed Firmware tab, verify for the correct firmware version.
Step 3          Log in to any controller VM through SSH.

# ssh root@controller_vm_ip
Step 4          Confirm the HyperFlex Data Platform version.

# stcli cluster version

Cluster version: 2.5(1c)
Node HX02 version: 2.5(1c)
Node HX05 version: 2.5(1c)
Node HX01 version: 2.5(1c)
Node HX03 version: 2.5(1c)
Node HX04 version: 2.5(1c)

Step 5          Verify that the HX storage cluster is online and healthy.

# stcli cluster info|grep -i health

Sample output:
healthstate : healthy
state: healthy
storage cluster is healthy

Step 6          Verify that the datastores are up and are mounted properly on the ESXi host.

From the HX controller VMs:
# stcli datastore list

From the ESXi host:
# esxcfg-nas -l
Step 7          For each browser interface you use, empty the cache and reload the browser page to refresh the HX Connect content.

Troubleshooting

Force Subordinate to PRIMARY

connect local-mgmt
cluster lead b 显示request failed local node is SUBORDINATE

# USE following parameters:
cluster force primary

désert/Cisco/FI-UCSM (last edited 2019-08-13 01:49:49 by 192)