更换RAID卡

  1. 确认RAID信息为空。
  2. 在服务器按F8进行P410i配制界面。
  3. 扫描drivers。
  4. 如果发现array则import array信息。
  5. 没有则ignore.

This can be done, with some caveats:

1. You must move the drives in the same order as that were in the system they came from. In other words, keep the SCSI ID's the same or at least in the same progression.

2. You should only migrate drives from and to the same type of controller. Here is a migration document that will help.
http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?locale=en_US&taskId=115&prodSeriesId=374783&prodTypeId=329290&objectID=c00180566

3. There are some problems moving the boot partiton arrays from one controller to another based upon the O/S installed and what drivers are used.

Otherwise this is commonly done.

If you have specific controllers and servers in mind, post those here and we can work out some details.

The RAID config is written to the disks themselves in a location dedicated to that purpose. The new array will read the disks and have access to the logical drives as before. They should be able to transfer to the new array controller without issue.

But as always, a backup before moving to the new server is a good idea.

# hpacucli
=> ctrl all show config