http://community.brocade.com/t5/Fibre-Channel-SAN/Swap-configuration-port-Dynamic-POD/td-p/26750
nys23bb89:USERID> configure
Configure...
- Fabric parameters (yes, y, no, n): [no] yes
- Domain: (1..239) [1] 101 R_A_TOV: (4000..120000) [10000] E_D_TOV: (1000..5000) [2000] WAN_TOV: (0..30000) [0] MAX_HOPS: (7..19) [7] Data field size: (256..2112) [2112] Sequence Level Switching: (0..1) [0] Disable Device Probing: (0..1) [0] Suppress Class F Traffic: (0..1) [0] Switch PID Format: (1..2) [1] Per-frame Route Priority: (0..1) [0] Long Distance Fabric: (0..1) [0] BB credit: (1..27) [16]
WARNING: The domain ID will be changed. The port level zoning may be affected
nys23bb89:USERID> switchName BladeE_FC_SW02 Committing configuration... Done. BladeE_FC_SW02:USERID>
BladeE_FC_SW02:USERID> switchEnable BladeE_FC_SW02:USERID> switchShow
BladeE_FC_SW02:USERID> msPlMgmtDeactivate Switch is in Offline state.
BladeE_FC_SW02:USERID> interopMode InteropMode: Off
Usage: InteropMode 0|1
- 0: to turn it off 1: to turn it on
BladeE_FC_SW02:USERID> interopMode 1 The switch effective configuration will be lost when the operating mode is changed; do you want to continue? (yes, y, no, n): [no] yes Interopmode is enabled
Note: It is recommended that you reboot this switch for the new change to take effect. BladeE_FC_SW02:USERID> fastBoot
Broadcast message from root (pts/0) Wed Aug 1 11:02:57 2001...
The system is going down for reboot NOW !!
BladeE_FC_SW02:USERID> portcfgpersistentenable 15 BladeE_FC_SW02:USERID> switchshow switchName: BladeE_FC_SW02 switchType: 37.1 switchState: Online switchMode: Native switchRole: Principal switchDomain: 107 switchId: fffc6b switchWwn: 10:00:00:05:1e:05:9c:df zoning: OFF switchBeacon: OFF
Area Port Media Speed State ==============================
- 0 0 id N4 No_Light 1 1 cu N4 Online F-Port 21:00:00:24:ff:2b:e9:15 2 2 cu N4 Online F-Port 21:01:00:1b:32:b7:fe:50 3 3 cu N4 Online F-Port 10:00:00:00:c9:b6:0b:85 4 4 cu N4 Online F-Port 10:00:00:00:c9:b6:15:6f 5 5 cu N4 Online F-Port 10:00:00:90:fa:49:8d:bb 6 6 cu N4 Online F-Port 10:00:00:90:fa:49:aa:bf 7 7 cu AN No_Sync 8 8 cu N4 Online F-Port 21:00:00:24:ff:59:f5:b5 9 9 cu N4 Online F-Port 21:00:00:24:ff:59:f5:c3
- 10 10 cu N4 Online F-Port 21:00:00:24:ff:59:f5:91 11 11 cu AN No_Sync 12 12 cu AN No_Sync 13 13 cu AN No_Sync 14 14 cu AN No_Sync 15 15 id N4 Online E-Port segmented,(FCSW version incompat) 16 16 -- N4 No_Module Disabled (Persistent) 17 17 -- N4 No_Module Disabled (Persistent) 18 18 -- N4 No_Module Disabled (Persistent) 19 19 -- N4 No_Module Disabled (Persistent)
BladeE_FC_SW02:USERID> portcfgpersistentenable Slot 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
+---+---+---+---+---+---+---+---+---+---+---+---+---+---+---+--- Enabled YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES
Slot 0 16 17 18 19
+---+---+---+--- Enabled - - - -